GY-TT300 User Manual
This manual introduces the three-axis inclination transmitter, its applications, measurement features and specifications. It covers switching and RS485/Modbus output options, dimensions, horizontal and vertical mounting, axis definitions, calibration requirements and wiring for structural inclination monitoring and equipment tilt measurement.
On this page

Inclinationtransmitterswitchtypeinstructionmanual
V1.0
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Inclinationtransmitter(switching
type)
UserManual

Inclinationtransmitterswitchtypeinstructionmanual
V1.0
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Thetiltangletransmitterisastandardindustrialthreeaxisinclinometer.Itcanbeusedoutdoorsfor
alongtimebydetectingthetiltangleintheuseenvironmenttojudgethetiltstateoftheequipment.
Itiswidelyusedinindustrialinclinationmeasurementanddangerousbuildingmonitoring,ancient
buildingprotectionmonitoring,bridgetowerinclinationmeasurement,tunnelmonitoring,dam
monitoring,weighingsysteminclinationcompensation,drillinginclinationcontrol,importantcounter
monitoringandotherindustries,safeandreliable,beautifulappearance,easytoinstall.
❏TheKalmanfilteralgorithmisusedtomaketheanglevaluescollectedbytheequipmentaccurateandstable.
❏Ithasawideanglemeasurementrangeandgoodoutputsignallinearity,whichcanbeusedinmostenvironments.
DCwidevoltagerangepowersupply.
❏Ithasthecharacteristicsofwidemeasurementrange,goodlinearity,convenientuse,easyinstallation,andlongtransmissiondistance.
DCpowersupply(default)
Maximumpower
consumption
Temperatureandhumidityresistanceof
equipmentcomponents
095%RH(noncondensation)
Anglerange
Resolution
Typicalaccuracy
X,Yaxis
Staticaccuracy1°,
Dynamicaccuracy1°
Zaxis
Staticaccuracy1°,
dynamicpresenceofintegralerror
Equipmentaccuracymeasurement
conditions
Ambienttemperature25℃,ambienthumidity45%RH,nochangeintheinstallationsurface,
nomagneticfielddry
Disturbance,equipmentafteronsitecalibration
Detection
frequency
Responsetime
Protectionlevel
DefaultCableLength
60cm,cablelengthcanbecustomized
accordingtorequirements
External
dimensions
Outputsignal
GYTT300DOswitchingvalueorGYTT300RS485(Modbusprotocol)
Theperformancedatapresentedabovewereobtainedunderthetestconditionsusingourcompany’stestingsystemandsoftware.
Inordertocontinuouslyimprovetheproducts,ourcompanyreservestherighttochangethedesignfunctionsandspecifications
withoutpriornotice.
1.ProductOverview
ProductOverview
Featuresand
Characteristics
Technical
Specifications

Inclinationtransmitterswitchtypeinstructionmanual
V1.0
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Equipmentdimensiondrawing(unit:mm)
2.Overalldimensionandinstallation
method
2.1dimensions
Scale1:1
Scale1:1
Scale1:1
Proportion

Inclinationtransmitterswitchtypeinstructionmanual
V1.0
DongguanYunjieIntelligentTechnologyCo.,Ltd.
2.2installation
method
Thedefaultinstallationdirectionofthemoduleishorizontalinstallation.Whenthemoduleneedstobeplacedvertically,theverticalinstallationsettingcanbe
used.
Verticalinstallation:Rotatethemodule90°abouttheXaxisintoaverticalposition.Inthe
PCconfigurationsoftware,setInstallationDirectiontoVertical,thencalibratebeforeuse.
Inthisorientation,Xpointshorizontallyright,Ypointsintothewall,andZfollowsthe
modulecounterclockwiserotationdirection.
3.Howto
Use
Pleaseinstalltheinclinationtransmitteraccordingtothecorrectinstallationmethod.
Incorrectinstallationwillcausemeasurementerrors,especiallytwo"faces"andtwo"lines":
(1)Theinstallationsurfaceoftheinclinationtransmitterandthemeasuredsurfacemustbetightly,flatand
stable.Iftheinstallationsurfaceisuneven,itiseasytocausethemeasurementangleerrorofthetransmitter.
(2)Theaxisoftheinclinationtransmittermustbeparalleltothemeasuredaxis,andthetwoaxesshouldnotform
anangleasmuchaspossible.
(3)Placethedeviceuprightonatable.Xpointsright,Ypointsupward,andZpointsoutward,
perpendiculartothetabletop.Rotationfollowstherighthandrule:pointyourrightthumb
alonganaxis;thecurledfingersindicateincreasingrotationaboutthataxis.X,YandZangles
describerotationabouttheirrespectiveaxes.
Leadwire
Description
Note
Red
Powersupply
positive(+)
Black
Powerground
(GND)
Yellow
Common
terminal
Blue
Normally
closed(NC)
white
Normally
open(NO)
NO(optional)
Installationdiagram
Avoidanglewiththemeasuredsurface
Sensor
Sensor
Error
Correct
Figure
1
Figure2
Sensor
Sensor
Axistobe
measured
Error
Correct
Figure3
Figure
4
4.EquipmentWiring
Instructions
Measured
plane
Measured
plane
Sensoraxis
Measured
plane
Parallel

Readabletextreferenceforsmalllabels
Sourcepage1
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Sourcepage2
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Sourcepage2
❏TheKalmanfilteralgorithmisusedtomaketheanglevaluescollectedbytheequipmentaccurateand
stable.
Sourcepage2
Maximumpowerconsumption
Sourcepage2
Temperatureandhumidityresistanceofequipmentcomponents
Sourcepage2
Typicalaccuracy
Sourcepage2
Dynamicaccuracy1°
Sourcepage2
dynamicpresenceofintegralerror
Sourcepage2
Equipmentaccuracymeasurementconditions
Sourcepage2
Disturbance,equipmentafteronsitecalibration
Sourcepage2
Detectionfrequency
Sourcepage2
Externaldimensions
Sourcepage3
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Sourcepage3
Proportion
Sourcepage4
DongguanYunjieIntelligentTechnologyCo.,Ltd.
Sourcepage4
Thedefaultinstallationdirectionofthemoduleishorizontalinstallation.Whenthemoduleneedstobe
placedvertically,theverticalinstallationsettingcanbeused.

Sourcepage4
Description
Sourcepage4
Powersupplypositive(+)
Sourcepage4
Powerground(GND)
Sourcepage4
Commonterminal
Sourcepage4
Normallyclosed(NC)
Sourcepage4
Normallyopen(NO)
Sourcepage4
Avoidanglewiththemeasuredsurface
Sourcepage4
Sensor
Sourcepage4
Sensor
Sourcepage4
Axistobemeasured
Sourcepage4
Measuredplane
Sourcepage4
Measuredplane
Sourcepage4
Measuredplane
Sourcepage4
Parallel