GY-ZNFB User Manual
This guide covers the explosion-proof magnetic door detector's drawings, specifications, normally open/normally closed signal options and wire identification. It explains switch and magnet placement, alignment and spacing, the effect of steel doors on sensing distance and the restriction against directly driving loads through the low-voltage contact.
On this page

DongguanYunjieIntelligentTechnologyCo.,
Ltd.
Explosionproofdoormagnetic
detector
Instructionsforexplosionproofdoormagnetic
detector
ProductDrawings:
Specifications:
Model
Signalmode
Threeoptions:Normallyclosed(NC),normallyopen(NO),or
combinedNO/NC.
Optionalprofiledefinition
Graywire:Common(COM);Redwire:Normallyopen(NO);Whitewire:Normallyclosed
(NC).
Explosionproof
marking
Ratedvoltage
Ratedcurrent
Work
environment
Enclosureprotectionrating
Sensingdistance
Normallyclosed
(NC):≥3cm
Normallyopen(NO):
≥2cm
Signalnote:Withtheswitchandmagnetbroughttogether,theNCcontactconductsandtheNOcontactis
open.
Doormagneticswitchinstallationmethodandmattersneeding
attention:
Thebeltswitchisinstalledonthedoorframe,themagnetisinstalledonthemovabledoororwindow,andthescrewisfixed;
Duringinstallation,theswitchandthemagnetshouldbealignedinparallel,andmisalignmentwillaffectthesensingdistanceofthe
switch;
Theinstallationdistancebetweentheswitchandthemagnetis≤1CM(thefactorytestdistanceofthis
doormagnetis23cm).Theinductiondistanceinstalledontheirondoorwillbegreatlyweakened,
andtheswitchwiththedistancegreaterthanthefactorymeasurementvaluewillloseitsfunction;
Thisswitchisaweakmagneticswitch,cannotbedirectlyloaded.
Installationdiagram:
Explosionproofdoormagnetic
detector

Readabletextreferenceforsmalllabels
Sourcepage1
Explosionproofdoormagneticdetector
Sourcepage1
Signalnote:Withtheswitchandmagnetbroughttogether,theNCcontactconductsandtheNOcontact
isopen.
Sourcepage1
Explosionproofdoormagneticdetector